Independent reviews of pressure, water-bath and steam canners, checked against USDA canning guidanceHow we make money
Guide

How to Test a Pressure Canner Gauge

Dial gauges drift. Since your safety depends on the pressure the dial says, it has to be checked.

Have a dial gauge tested every year before canning season and after any drop, usually at a county extension office or through the canner's maker, and replace it if it reads more than 2 pounds off at 5, 10 or 15 pounds.

Updated November 16, 2026 · By the editors of Home Canning Report · We earn from qualifying purchases

When to test

  • Once a year before you start canning.
  • After the canner or lid is dropped.
  • If the glass is cracked, the needle doesn't rest at zero, or there's rust.
  • After the gauge has been submerged.

Where to get it tested

Call your county Cooperative Extension office; many test common gauges, especially Presto, for free or a small fee. Presto also offers testing for its gauges. Bring only the lid.

If it's off

NCHFP's guidance: if it reads off by less than 2 pounds at 5, 10 or 15 pounds, you can adjust your processing pressure to compensate; if it's more than 2 pounds off, replace it. Replacement gauges are inexpensive.

Weighted gauges

Weighted regulators don't need testing. Keep the vent pipe clear and the weight undamaged. That's a big reason some people prefer the All American or Presto's 3-piece regulator.

Questions

Can I test a gauge at home?

Not reliably. Testers compare the gauge to a certified master gauge. Use an extension office or the maker.

Does an All American dial need testing?

You go by the weighted regulator on an All American, which doesn't need testing.

Keep reading